Portable Color Doppler Ultrasound Machine for Abdomen
$2100-3500 /Set/Sets
Payment Type: | T/T |
Incoterm: | FOB |
Min. Order: | 5 Set/Sets |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Payment Type: | T/T |
Incoterm: | FOB |
Min. Order: | 5 Set/Sets |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Ningbo,Shanghai |
Model No.: MDK-680
Brand: United Ultrasound
Color: white
Brand: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Place Of Origin: China
Kind Of Power: Electricity
Warranty Service: 1 Year
After-sales Service: Free Spare Parts, Online Technical Support
Material: Metal, Plastic
Medical Device Classification: Class Ii
Selling Units | : | Set/Sets |
Package Type | : | Carton |
The file is encrypted. Please fill in the following information to continue accessing it
Portable Color Doppler Ultrasound Machine for Abdomen(MDK-680)
It is mainly used in liver and kidney, but it has certain auxiliary diagnostic value for distinguishing benign and malignant lesions in abdominal cavity, gallbladder cancer from large polyps, chronic and severe inflammation, and the difference between common bile duct and hepatic artery.
Color ultrasound can be used to determine the size of the lumen, the speed and direction of the internal flow and the establishment of collateral circulation in liver cirrhosis. For nodular sclerosis and diffuse liver cancer, which are extremely difficult to distinguish between black and white, it can facilitate the differential diagnosis by high-frequency exploration and blood flow spectrum exploration.
For the differential diagnosis of benign and malignant hepatic space occupying lesions, cysts and various arteriovenous tumors have better diagnostic value. Primary liver cancer and secondary liver cancer can also be distinguished by the internal blood supply.
Color ultrasound is mainly used in kidney for renal vascular diseases. As mentioned above, when the clinical manifestations are septal and painless hematuria, the cause can not be found, there are strong adaptation signs. For renal artery stenosis, one of the common causes of secondary hypertension, color ultrasound can make a clear diagnosis basically. When the blood flow rate at the stenosis was more than 150cm/s, the diagnostic accuracy reached 98.6%, and the sensitivity was 100%. On the other hand, it is also the differential diagnosis of renal carcinoma, transitional carcinoma of renal pelvis and benign tumor.
Our products:
Black and White Ultrasound Scanner
Color Doppler Ultrasound Scanner
Veterinary Ultrasound Scanner
No. Item Index <1> Depth ≥300mm <2> Lateral Resolution ≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) <3> Axial Resolution ≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) <4> Blind Area ≤4 mm <5> Geometry Position Precision horizontal≤5% vertical≤5% <6> Language English/Chinese <7> Channels 32 <8> Displayer 12” LED <9> External Display PAL, VGA, USB <10> Gray Scale 256 levels <11> Voltage AC220V ±10% <12> Operating System Windows 7 <13> Scanning Mode B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW <14> Probe Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion <15> Adjustment parameters of color blood flow image Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc <16> Signal processing With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively <17> Doppler Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation <18> Digital beam forming Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology <19> Basic measurement and calculation function Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section Basic measurement of M-mode: heart rate, time, distance and speed Doppler measurement: time, heart rate, speed, acceleration <20> Gynecological measurement and calculation function Measurement and calculation of uterus, left ovary, right ovary, left follicle, right follicle, etc <21> Obstetric measurement and calculation function G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD <22> Urology measurement and calculation function Measurement and calculation of left kidney, right kidney, bladder, residual urine volume, prostate, prostate specific antigen predicted value PPSA, prostate specific antigen density PSAD, etc <23> Product Size 289×304×222mm <24> Carton Size 395×300×410mm <25> N.W./ G.W. 6kg/ 7kg
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.